Package Overview
Placon, a leader in medical device packaging, recently worked with a major orthopedic device manufacturer to develop a custom double sterile-barrier blister assembly for a next-generation implant system used to treat chronic insertional Achilles tendon pathology. The five-component package, made up of an Outer Tray, Inner Tray, Retainer, and two independent Tyvek lids, forms a validated double sterile-barrier system. It replaced the multiple thermoformed sterile-barrier subassemblies and tray configurations previously needed to hold the implants, single-use instruments, and surgical technique components.
The challenge facing Placon was that the new packaging assembly includes more implant and instrument components than prior versions, yet hospital storage constraints required the same footprint as its predecessor. The result is a single compact assembly that accommodates all 8 product configurations in the family.
Economics
The previous multi-package approach compounded costs throughout the supply chain: more raw material, a larger warehousing footprint, higher per-kit assembly labor, multiple sealing and lidding operations, added sterilization handling, and greater risk of component separation or loss at the point of care. Placon’s consolidated assembly addresses each of these concerns.
Environmental Impact
Placon designed the assembly to minimize environmental impact across the package life cycle. Consolidating multiple subassemblies into one was the most consequential decision. It reduces total packaging material per procedure and eliminates the waste of opening and disposing of multiple pckages in the operating room.
Innovation
The defining innovation is a five-component double sterile-barrier assembly that holds all 8 configurations within a fixed footprint. Its nested design gives implantable components independent layers of sterility protection, while the Inner Tray and Retainer manage component variety and positional control across every variant.
Marketing
In the medical device market, packaging extends the product brand and signals quality to clinical customers. The Achilles repair system is a premium solution for orthopedic surgeons and OR teams. A clean, compact, unified assembly reinforces its positioning as a streamlined, next-generation approach, while the double barrier communicates an elevated commitment to sterility assurance for implants.
Package Performance
The assembly was designed with the manufacturer’s operations in mind. The Outer Tray, Inner Tray, and Retainer nest in a defined sequence for efficient manual loading and consistent positioning before the two-lid sealing operation. In the OR, the lids peel open sequentially: the outer Tyvek lid is peeled to access the first barrier, then the inner lid is peeled to present the Inner Tray and Retainer contents to the sterile field, maintaining aseptic technique throughout.
Product Protection
The kit’s sterile, single-use implants and precision instruments must arrive at the point of care sterile, dimensionally intact, and fully functional. Two independently validated sterile barriers provide an elevated level of sterility assurance, particularly appropriate for implantable orthopedic anchors.
Our Process
Our Facilities
Contact us